Home / Expert Answers / Chemical Engineering / 3-the-storage-tank-system-shown-in-the-given-figure-is-used-to-store-process-feedstock-overfi-pa231

(Solved): 3. The storage tank system shown in the given Figure is used to store process feedstock. Overfi ...



3. The storage tank system shown in the given Figure is used to store process feedstock. Overfilling of storage tanks is a co

3. The storage tank system shown in the given Figure is used to store process feedstock. Overfilling of storage tanks is a common problem in the process industries. To prevent overfilling, the storage tank is equipped with a high-level alarm and a high-level shutdown system. The high-level shutdown system is connected to a solenoid valve that stops the flow of input stock. Develop a fault tree for the top event of "storage tank overflows." [?]


We have an Answer from Expert

View Expert Answer

Expert Answer



To develop a fault tree for the top event of "storage tank overflows" we can break down the potential causes and contributing factors that could lead to this event. heres an example of a fault tree for this scenario:

Top event: storage tank overflows

1. HIGH-LEVEL ALARAM FAILURE

High-level alarm sensor malfunction
faulty alarm circuitry
Alarm system power failure
We have an Answer from Expert

Buy This Answer $5

Place Order